Ultra-low iodine concentrations iso-attenuating with diagnostic 0.5 M gadolinium in endovascular procedures to minimize the risk of contrast nephropathy: A phantom study

  • 1. Department of Radiology, Oncology and Radiation Sciences, Section of Radiology, Uppsala University Hospital, SE-751 85 Uppsala (Sweden)
  • 2. Department of Medical Physics, Uppsala University Hospital, SE-751 85 Uppsala (Sweden)
  • 3. Institution of Clinical Sciences, Lund University, SE-221 00 Lund (Sweden)

Description

Purpose: To establish the concentrations of iodine contrast media (I-CM) iso-attenuating with 0.5 M gadolinium contrast media (Gd-CM), regarded diagnostic in catheter angiography and vascular interventions in azotemic patients, at various X-ray tube potentials with correlation to skin radiation dose. Materials and method: 20-mL syringes filled with 30, 40, 50, 70 and 90 mg I/mL, 0.5 M Gd-CM and air were placed in a water-equivalent phantom and exposed at about 50, 60, 70, 80 and 90 kV in an X-ray angiographic system. Relative contrast between the contrast materials and the background phantom material was measured on a PACS workstation. Radiation entrance dose, measured with a dose meter and estimated from the dose-area-product (DAP), was adjusted for radiation backscatter to simulate absorbed skin dose. Result: The iodine concentrations 30, 40, 50, 70 and 90 mg/mL resulted in the same relative contrast as 0.5 M gadolinium at 53, 57, 62, 71 and 85 kVp, respectively. Air had lower relative contrast than all iodine concentrations at all kVp-settings except for 30 mg I/mL above 84 kVp. The measured skin radiation dose was less than 1 mGy per exposure at all kVp-settings, and around 25–30% lower than the dose estimations derived from the angiographic system's in-built DAP meter. Conclusion: Low-kilovoltage X-ray technique and ultra-low concentrations of I-CM iso-attenuating with 0.5 M Gd-CM may be utilizable in peripheral arteriography and endovascular interventions, to minimize the total CM-dose to avoid CIN in azotemic patients

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejrad.2015.03.014

Additional details

Identifiers

DOI
10.1016/j.ejrad.2015.03.014;
PII
S0720-048X(15)00136-9;

Publishing Information

Journal Title
European Journal of Radiology
Journal Volume
84
Journal Issue
6
Journal Page Range
p. 1068-1074
ISSN
0720-048X
CODEN
EJRADR

Optional Information

Copyright
Copyright (c) 2015 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.