Published August 2014 | Version v1
Journal article

Proton irradiation effect on SCDs

  • 1. Key Laboratory for Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences (CAS), 19B Yuquan Road, Beijing (China)
  • 2. College of Physics, Jilin University, Changchun (China)

Description

The Low Energy X-ray Telescope is one of the main payloads on the Hard X-ray Modulation Telescope satellite. Swept charge devices (SCDs) are selected as detectors for the Low Energy X-ray Telescope. As SCDs are sensitive to proton irradiation, irradiation tests were carried out on the HI-13 accelerator at the China Institute of Atomic Energy. The beam energy was measured to be 10 MeV at the SCD. The proton fluence delivered to the SCD was 3 × 108 protons cm2 over two hours. By comparing the performance before and after irradiation, it is concluded that proton irradiation affects both the dark current and the charge transfer inefficiency of the SCD. The energy resolution of the proton-irradiated SCD is 212 eV doped 5.9 keV at -60℃, while it before irradiated is 134 eV. Moreover, better performance can be reached by lowering the operating temperature of the SCD in orbit. (authors)

Additional details

Publishing Information

Journal Title
Chinese Physics. C, High Energy Physics and Nuclear Physics
Journal Volume
38
Journal Issue
8
Journal Page Range
[4 p.]
ISSN
1674-1137

Optional Information

Notes
10 figs., 1 tab., 8 refs.; http://dx.doi.org/10.1088/1674-1137/38/8/086004