Published 1991 | Version v1
Report

Beam diagnostics for the 400 MeV Fermilab linac

  • 1. Fermi National Accelerator Lab., Batavia, IL (United States)

Description

Prototype beam diagnostics for the 400 MeV linac are being designed and tested. These new diagnostics include: wire scanners, stripline beam position monitors which fit within the quadrupoles, Tevatron-style resistive wall-current monitors and Feschenko-style bunch length detectors. Several of these devices have been tested with 116 MeV and 200 MeV H- beam in the present 200 MeV linac

Additional details

Publishing Information

Imprint Title
Conference record of the 1991 IEEE particle accelerator conference: Accelerator science and technology. Volume 2 of 5
Imprint Pagination
724 p.
Journal Page Range
p. 1249-1251.
Report number
DOE/ER/40607--1-Vol.2

Conference

Title
1991 Institute of Electrical and Electronics Engineers (IEEE) particle accelerator conference (PAC).
Dates
6-11 May 1991.
Place
San Francisco, CA (United States).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
24001945
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
BEAM BUNCHING; BEAM CURRENTS; BEAM MONITORS; BEAM SCANNERS; DESIGN; ELECTRODES; ENERGY LOSSES; FERMILAB ACCELERATOR; FERMILAB TEVATRON; HYDROGEN 1 MINUS BEAMS; LINEAR ACCELERATORS; PERFORMANCE TESTING; QUADRUPOLES
Descriptors DEC
ACCELERATORS; BEAM DYNAMICS; BEAMS; CURRENTS; CYCLIC ACCELERATORS; DYNAMICS; ION BEAMS; MEASURING INSTRUMENTS; MECHANICS; MONITORS; MULTIPOLES; SYNCHROTRONS; TESTING

Optional Information

Secondary number(s)
CONF-910505--Vol.2.