Published 1991
| Version v1
Report
Beam diagnostics for the 400 MeV Fermilab linac
- 1. Fermi National Accelerator Lab., Batavia, IL (United States)
Description
Prototype beam diagnostics for the 400 MeV linac are being designed and tested. These new diagnostics include: wire scanners, stripline beam position monitors which fit within the quadrupoles, Tevatron-style resistive wall-current monitors and Feschenko-style bunch length detectors. Several of these devices have been tested with 116 MeV and 200 MeV H- beam in the present 200 MeV linac
Additional details
Publishing Information
- Imprint Title
- Conference record of the 1991 IEEE particle accelerator conference: Accelerator science and technology. Volume 2 of 5
- Imprint Pagination
- 724 p.
- Journal Page Range
- p. 1249-1251.
- Report number
- DOE/ER/40607--1-Vol.2
Conference
- Title
- 1991 Institute of Electrical and Electronics Engineers (IEEE) particle accelerator conference (PAC).
- Dates
- 6-11 May 1991.
- Place
- San Francisco, CA (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 24001945
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- BEAM BUNCHING; BEAM CURRENTS; BEAM MONITORS; BEAM SCANNERS; DESIGN; ELECTRODES; ENERGY LOSSES; FERMILAB ACCELERATOR; FERMILAB TEVATRON; HYDROGEN 1 MINUS BEAMS; LINEAR ACCELERATORS; PERFORMANCE TESTING; QUADRUPOLES
- Descriptors DEC
- ACCELERATORS; BEAM DYNAMICS; BEAMS; CURRENTS; CYCLIC ACCELERATORS; DYNAMICS; ION BEAMS; MEASURING INSTRUMENTS; MECHANICS; MONITORS; MULTIPOLES; SYNCHROTRONS; TESTING
Optional Information
- Secondary number(s)
- CONF-910505--Vol.2.