Published 1985 | Version v1
Report Restricted

Development of an asymmetric multiple-position neutron source (AMPNS) method to monitor the criticality of a degraded reactor core

  • 1. Pennsylvania State Univ., University Park

Description

An analytical/experimental method has been developed to monitor the subcritical reactivity and unfold the k/sub infinity/ distribution of a degraded reactor core. The method uses several fixed neutron detectors and a Cf-252 neutron source placed sequentially in multiple positions in the core. Therefore, it is called the Asymmetric Multiple Position Neutron Source (AMPNS) method. The AMPNS method employs nucleonic codes to analyze the neutron multiplication of a Cf-252 neutron source. An optimization program, GPM, is utilized to unfold the k/sub infinity/ distribution of the degraded core, in which the desired performance measure minimizes the error between the calculated and the measured count rates of the degraded reactor core. The analytical/experimental approach is validated by performing experiments using the Penn State Breazeale TRIGA Reactor (PSBR). A significant result of this study is that it provides a method to monitor the criticality of a damaged core during the recovery period

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Title
Workshop on subcritical reactivity measurements: proceedings
Journal Page Range
p. 49-83.
Report number
CONF-8508105--

Conference

Title
DOE subcritical reactivity measurements workshop.
Dates
26-29 Aug 1985.
Place
Albuquerque, NM (USA).