Published August 1976
| Version v1
Report
Bases for plugging degraded PWR steam generator tubes
Description
The guide describes a method acceptable to the NRC staff for establishing the limiting safe conditions of tube degradation of steam generator tubing, beyond which defective tubes as established by inservice inspection should be removed from service by welding plugs at each end of the tube. The guide applies only to pressurized water reactors
Additional details
Publishing Information
- Imprint Pagination
- 8 p.
- Report number
- REG/G--1.121(8-76)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 8297093
- Subject category
- S99: GENERAL AND MISCELLANEOUS; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- CLOSURES; LEAKS; MAINTENANCE; PWR TYPE REACTORS; REGULATORY GUIDES; REPAIR; STEAM GENERATORS; TUBES
- Descriptors DEC
- BOILERS; DOCUMENT TYPES; REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- NUREG.