Bases for plugging degraded PWR steam generator tubes

Description

The guide describes a method acceptable to the NRC staff for establishing the limiting safe conditions of tube degradation of steam generator tubing, beyond which defective tubes as established by inservice inspection should be removed from service by welding plugs at each end of the tube. The guide applies only to pressurized water reactors

Additional details

Publishing Information

Imprint Pagination
8 p.
Report number
REG/G--1.121(8-76)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
8297093
Subject category
S99: GENERAL AND MISCELLANEOUS; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
CLOSURES; LEAKS; MAINTENANCE; PWR TYPE REACTORS; REGULATORY GUIDES; REPAIR; STEAM GENERATORS; TUBES
Descriptors DEC
BOILERS; DOCUMENT TYPES; REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS

Optional Information

Notes
NUREG.