Published 1990 | Version v1
Journal article

Determination of inlet temperature field using mixing factors

  • 1. Paksi Atomeroemue Vallalat, Paks (Hungary)

Description

In the V-213 type nuclear reactor the measurement of inlet temperature from one assembly to another is not yet solved technically. Therefore, the inlet temperature could be deduced from thermometer signals that were positioned in the cold loops. The experimental determination of the temperature field below the reactor core, and the mixing factors are presented. It made possible the online calculation of the assembly inlet temperature even for asymmetric core cooling conditions. (R.P.) 5 refs.; 4 figs

Additional details

Additional titles

Original title (Hungarian)
A belepoehoemerseklet-mezoe meghatarozasa keveredesi tenyezoek segitsegevel

Publishing Information

Journal Title
PAV Koezlemenyek
Journal Issue
no.2
Series
PAV Koezl.
ISSN
0865-4859
CODEN
PAKOE