Published January 1985 | Version v1
Report Open

Report on tests using a flow visualization rig - two channel per pass configuration

  • 1. Monserco Ltd., Montreal (Canada)

Description

The flow visualization rig at Monserco Limited has been modified and commissioned, and then used to conduct several tests with two channels in each pass. Single phase thermosyphoning in the rig was demonstrated, and two phase experiments with different starting conditions were done. Results of the tests are presented here. The two phase tests resulted in flow patterns with the same characteristics, independent of the starting condition. Based on results presented here, a recommendation for adding another heated channel in each pass is made

Availability note (English)

MF available from INIS under the Report Number.

Files

16078239.pdf

Files (1.3 MB)

Name Size Download all
md5:f2b0ecec48d6d8ff80ae7a262b6a1702
1.3 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
96 p.
Report number
INFO--0148-1

Optional Information

Contract/Grant/Project number
Contract 02SQ.84055-3-4111