Published December 1985 | Version v1
Report Restricted

Initial decontamination of the equipment decontamination room at the West Valley Demonstration Project. Topical report, September 1983-May 1985

Description

The purpose of this report is to document the initial decontamination of the Equipment Decontamination Room (EDR). The effort spanned a two-year period and included packaging and removal of waste; grinding away contaminated concrete floors; pump-out and spraydown of an equipment soaking pit; washing and painting of walls, equipment, and floors; refurbishment of utilities and various pieces of equipment; and load tests of EDR and Chemical Process Cell (CPC) cranes. After decontamination, the EDR was converted into a waste handling area for the decommissioning of the CPC

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A03/MF A01; 1 as DE86010128.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
49 p.
Report number
DOE/NE/44139--2

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
17083706
Subject category
S12: MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES;
Descriptors DEI
BUILDINGS; COST; DECONTAMINATION
Descriptors DEC
CLEANING

Optional Information

Notes
Portions of this document are illegible in microfiche products. Original copy available until stock is exhausted.