Inter-crystal scatter identification for a depth-sensitive detector using support vector machine for small animal positron emission tomography
Creators
- 1. National Institute of Radiological Sciences, Anagawa 4-9-1 Inage-ku, Chiba-shi, Chiba 263-8555 (Japan)
- 2. Shimadzu Corporation, Nishinokyo Kuwabaracho 1 Nakagyo-ku, Kyoto-shi, Kyoto 604-8511 (Japan)
- 3. Tokyo Metropolitan Institute of Gerontology, Nakamachi 1-1 Itabashi-ku, Tokyo 173-0022 (Japan)
Description
In a conventional positron emission tomography (PET) detector, detected events are projected onto a 2D position histogram by an Anger calculation for crystal identification. However, the measured histogram is affected by inter-crystal scatterings (ICS) which occur in the entire detector. Peaks which are projected for each crystal in the histogram are blurred, and this causes ICS mispositioning. A depth-of-interaction (DOI) detector has been developed for the small animal PET scanner jPET-RD. This DOI detector uses 32x32 crystals with four layers and a 256-channel multi-anode flat panel photomultiplier tube (FP-PMT) which was developed by Hamamatsu Photonics K.K. Each crystal element is 1.45x1.45x4.5 mm3. The FP-PMT has a large detective area (49x49 mm2) and a small anode pitch (3.04 mm). Therefore, the FP-PMT can extensively trace the behavior of incident γ rays in the crystals including ICS event. We, therefore, propose a novel method for ICS estimation using a statistical pattern recognition algorithm based on a support vector machine (SVM). In this study, we applied the SVM for discriminating photoelectric events from ICS events generated from multiple-anode outputs. The SVM was trained by uniform irradiation events generated from a detector simulator using a Monte Carlo calculation. The success rate for ICS event identification is about 78% for non-training data. The SVM can achieve a true subtraction of ICS events from measured events, and it is also useful for random correction in PET
Additional details
Identifiers
- DOI
- 10.1016/j.nima.2006.10.073;
- PII
- S0168-9002(06)01870-5;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 571
- Journal Issue
- 1-2
- Journal Page Range
- p. 243-246
- ISSN
- 0168-9002
- CODEN
- NIMAER
Conference
- Title
- 1. international conference on molecular imaging technology
- Acronym
- EuroMedIm 2006
- Dates
- 9-12 May 2006
- Place
- Marseille (France)
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 38092099
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ALGORITHMS; ANIMALS; ANODES; CORRECTIONS; CRYSTALS; DEPTH; GAMMA RADIATION; IRRADIATION; LAYERS; MONTE CARLO METHOD; PATTERN RECOGNITION; PHOTOMULTIPLIERS; POSITRON COMPUTED TOMOGRAPHY; SCATTERING; SIMULATORS
- Descriptors DEC
- ANALOG SYSTEMS; CALCULATION METHODS; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DIMENSIONS; ELECTRODES; ELECTROMAGNETIC RADIATION; EMISSION COMPUTED TOMOGRAPHY; FUNCTIONAL MODELS; IONIZING RADIATIONS; MATHEMATICAL LOGIC; PHOTOTUBES; RADIATIONS; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.