Published January 1996 | Version v1
Report Open

Maximum total organic carbon limits at different DWPF melter feed maters (U)

Description

The document presents information on the maximum total organic carbon (TOC) limits that are allowable in the DWPF melter feed without forming a potentially flammable vapor in the off-gas system were determined at feed rates varying from 0.7 to 1.5 GPM. At the maximum TOC levels predicted, the peak concentration of combustible gases in the quenched off-gas will not exceed 60 percent of the lower flammable limit during a 3X off-gas surge, provided that the indicated melter vapor space temperature and the total air supply to the melter are maintained. All the necessary calculations for this study were made using the 4-stage cold cap model and the melter off-gas dynamics model. A high-degree of conservatism was included in the calculational bases and assumptions. As a result, the proposed correlations are believed to by conservative enough to be used for the melter off-gas flammability control purposes

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE97003353; NTIS; US Govt. Printing Office Dep.

Files

28057501.pdf

Files (700.8 kB)

Name Size Download all
md5:6b2a1e21ac0b81d8c535cbd8f37995e4
700.8 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
37 p.
Report number
WSRC-TR--95-0294-Rev.1