Published May 12, 2004 | Version v1
Journal article

Interferometric phase-contrast X-ray CT imaging of VX2 rabbit cancer at 35keV X-ray energy

  • 1. Institute of Clinical Medicine, University of Tsukuba, Tsukuba-shi, Ibaraki 305-8575 (Japan)
  • 2. Advanced Research Laboratory, Hitachi, Ltd., Hatoyama, Saitama, 350-0395 (Japan)
  • 3. Material Structure Science, High Energy Accelerator Research Organization, Tsukuba 305-0801 (Japan)

Description

Imaging of large objects at 17.7-keV low x-ray energy causes huge x-ray exposure to the objects even using interferometric phase-contrast x-ray CT (PCCT). Thus, we tried to obtain PCCT images at high x-ray energy of 35keV and examined the image quality using a formalin-fixed VX2 rabbit cancer specimen with 15-mm in diameter. The PCCT system consisted of an asymmetrically cut silicon (220) crystal, a monolithic x-ray interferometer, a phase-shifter, an object cell and an x-ray CCD camera. The PCCT at 35 keV clearly visualized various inner structures of VX2 rabbit cancer such as necrosis, cancer, the surrounding tumor vessels, and normal liver tissue. Besides, image-contrast was not degraded significantly. These results suggest that the PCCT at 35 KeV is sufficient to clearly depict the histopathological morphology of VX2 rabbit cancer specimen

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
705
Journal Issue
1
Journal Page Range
p. 1328-1331
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
8. international conference on synchrotron radiation instrumentation
Dates
25-29 Aug 2003
Place
San Francisco, CA (United States)

Optional Information

Notes
(c) 2004 American Institute of Physics