Published November 1980 | Version v1
Journal article

Sampling of airborne radioactivity in a hot fuel examination facility

  • 1. Louisiana State Univ., Baton Rouge (USA)
  • 2. Argonne National Lab., IL (USA)

Description

To ensure the maintenance of a safe working environment, and provide data of interest to operations personnel, a fixed air sampling system (FASS) has been installed at the Hot Fuel Examination Facility/North at Argonne National Laboratory's Idaho site. A design requirement is that the system be operated with a minimum number of person-hours. Sixty-six sampling stations are located throughout the facility to gather data from areas where personnel are normally present without respiratory protection. The effectiveness of in-cell contamination-control programs and materials-handling procedures can be evaluated. Long-term trends are valuable guides to improving radiological controls while airborne activities are still well below operational guidelines. Since the beginning of operation in August 1976, the concentrations have averaged between 1x10-15 and 5x10-15μCi/cm3 for α emitters and from 4x10-14 to 4x10-13μCi/cm3 for β-γ emitters. Such values are well below the radiation concentration guides. (author)

Additional details

Publishing Information

Journal Title
Health Phys.
Journal Volume
39
Journal Issue
5
Series
Health Phys.
Journal Page Range
737-750