Implementation and acceptance of dynamic MLC for IMRT and VMAT
Creators
- 1. ALIADA, Oncologia Integral, Av. Jose Galvez Barrenechea 1044, San Isidro, Lima 27 (Peru)
Description
The use of Multi-leaf Collimator (MLC) in Intensity-Modulated Radiation Therapy (IMRT) for dynamic treatment techniques as Volumetric Modulated Arc Therapy (VMAT) makes that the movement controls as the speed of the MLC are quantified by means of an acceptance test. The objective determination of the operation regulations of the radiotherapy equipment requires ideally the establishment of the quantitative relationship among the performance deviations and clinical results or some acceptable substitute. Different protocols exist detailed with parameters and acceptance ranges according to the MLC thickness. In our case the acceptance test was carried out for 120-MLC of Trilogy equipment brand Varian. For all the test were used 300-200 Um for each formed beam lets; source-surface distance (SSD) of 100 cm. 9 acceptance tests were used each one with different purposes like to quantify, synchronization, stability, complexity, precision, positioning, conformity, dynamic movements for the case of dynamic wedges, consecutive moves, among others, for the measurements were used film badges dosimetry (Gafchromic Ebt-3 scanner Epson expression 10000 XL); additionally the results were compared with a diodes arrangement Map-Check 2 brand Sun Nuclear; that consists of 1527 diodes prepared in a field of 32 x 26 cm located at a distance of 1 cm parallel, 0.5 cm diagonally. All the developed tests were inside the acceptance tolerance parameters when comparing the obtained result regarding the badges and the Map-Check was found a discrepancy of 0.01%, what gives a treatment certainty to the moment to impart volumetric dose in dynamic fields to the patients. (Author)
Files
46021472.pdf
Files
(490.1 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:c99873aeffc4c78af97d0a47036e658b
|
490.1 kB | Preview Download |
Additional details
Additional titles
- Original title (Spanish)
- Implementacion y aceptacion de MLC dinamicos para IMRT y VMAT
Publishing Information
- Publisher
- Sociedad Mexicana de Irradiacion y Dosimetria
- Imprint Place
- Mexico, D. F. (Mexico)
- Imprint Pagination
- 11 p.
- Report number
- INIS-MX--2820
Conference
- Title
- 14. International Symposium on Solid State Dosimetry
- Original Conference Title
- 14. Conferencia Internacional sobre Dosimetria de Estado Solido
- Dates
- 13-16 Apr 2014
- Place
- Cusco (Peru)
INIS
- Country of Publication
- Mexico
- Country of Input or Organization
- Mexico
- INIS RN
- 46021472
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACCURACY; BEAMS; COLLIMATORS; COMPARATIVE EVALUATIONS; DISTANCE; DOSES; DOSIMETRY; EQUIPMENT; IMPLEMENTATION; LET; OPERATION; PATIENTS; PERFORMANCE; PHOTOGRAPHIC FILM DOSEMETERS; POSITIONING; RADIOTHERAPY; REGULATIONS; STABILITY; SYNCHRONIZATION; THICKNESS
- Descriptors DEC
- DIMENSIONS; DOSEMETERS; ENERGY TRANSFER; EVALUATION; LAWS; MEASURING INSTRUMENTS; MEDICINE; NUCLEAR MEDICINE; RADIOLOGY; THERAPY
Optional Information
- Funding organization
- Organizacion Panamericana de la Salud, Washington D. C. (United States); Universidad Nacional de San Antonio de Abad del Cusco, Cusco (Peru); Instituto Peruano de Energia Nuclear, Lima (Peru); Elekta AB (Sweden); RadPro International GmbH (Germany); ThermoFisher Scientific, Inc. (United States); Varian Medical Systems (United States)