Published October 2013 | Version v1
Miscellaneous

Wear on Plugged Tube due to the Foreign Objects on the Secondary Side of Steam Generator

  • 1. Korea Hydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of)

Description

In this paper, the changes of the tube frequency and amplitude are introduced before and after plugging. The amplitude of the bottom span for the steam generator tube is not much changed after tube plugging. Moreover, the contact force between the plugged tube and the foreign object is the same as that of intact tube and the foreign object. However, the frequencies of plugged tubes are about 9∼12% higher than those of intact tubes. That means the wear due to the foreign object would be accelerated after the tube plugging. Therefore, the tube stabilizer should be installed when the tube is plugged due to the foreign object wear. The tube wall of steam generator is a pressure boundary between the coolant of the primary system and the feedwater of the secondary system. It is very important to insure the structural integrity of the tubes because the radioactive coolant is flow into the feedwater due to the pressure difference as the result of tube failure. The degradations of steam generator tubes are corrosion, wear, fatigue and foreign object wear, etc. The foreign object wear is one of mechanical degradation due to materials flew into the secondary side of steam generator. The steam generator tubes, estimated not to insure structural integrity from the results of the nondestructive evaluation such as eddy current test and visual inspection, are excluded from the service with plugging. However, the tube wear is still being progressed after the plugging because the relative motion between the tube and structure is still existed due to the secondary side flow in the steam generator. If the tube is completely cut because of the degradation, the tube can be a stress or of failure of tubes around the plugged tube. The contact force between the structure and tube is lowered as the wear is progressed. However, the contact force between the foreign object and tube is not changed as the wear is progressed. Therefore, the structural integrity of tubes around the foreign object could not be insured unless the foreign object is removed. Plugged tubes due to the foreign objects would continuously be worn. It can be easily imagined that the frequencies and amplitudes, which are the essential variables of the tube wear calculation, should be changed because there is no coolant in the plugged tubes

Part of:
Proceedings of the KNS Fall meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Daejeon (Korea, Republic of)
Imprint Title
Proceedings of the KNS Fall meeting
Imprint Pagination
[1 CD-ROM]
Journal Page Range
[2 p.]

Conference

Title
2013 Fall meeting of the KNS
Dates
23-25 Oct 2013
Place
Kyungju (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
45082487
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
COOLANTS; CORROSION; EDDY CURRENT TESTING; FEEDWATER; INSPECTION; STEAM GENERATORS; TUBES; WEAR
Descriptors DEC
BOILERS; CHEMICAL REACTIONS; ELECTROMAGNETIC TESTING; HYDROGEN COMPOUNDS; MATERIALS TESTING; NONDESTRUCTIVE TESTING; OXYGEN COMPOUNDS; TESTING; VAPOR GENERATORS; WATER

Optional Information

Notes
4 refs, 2 figs, 1 tab