Published February 2004 | Version v1
Journal article

A deformable-model approach to semi-automatic segmentation of CT images demonstrated by application to the spinal canal

  • 1. Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, Texas 77030 (United States)
  • 2. Department of Radiation Physics, University of Texas M.D. Anderson Cancer Center, Houston, Texas 77030 (United States)

Description

Because of the importance of accurately defining the target in radiation treatment planning, we have developed a deformable-template algorithm for the semi-automatic delineation of normal tissue structures on computed tomography (CT) images. We illustrate the method by applying it to the spinal canal. Segmentation is performed in three steps: (a) partial delineation of the anatomic structure is obtained by wavelet-based edge detection; (b) a deformable-model template is fitted to the edge set by chamfer matching; and (c) the template is relaxed away from its original shape into its final position. Appropriately chosen ranges for the model parameters limit the deformations of the template, accounting for interpatient variability. Our approach differs from those used in other deformable models in that it does not inherently require the modeling of forces. Instead, the spinal canal was modeled using Fourier descriptors derived from four sets of manually drawn contours. Segmentation was carried out, without manual intervention, on five CT data sets and the algorithm's performance was judged subjectively by two radiation oncologists. Two assessments were considered: in the first, segmentation on a random selection of 100 axial CT images was compared with the corresponding contours drawn manually by one of six dosimetrists, also chosen randomly; in the second assessment, the segmentation of each image in the five evaluable CT sets (a total of 557 axial images) was rated as either successful, unsuccessful, or requiring further editing. Contours generated by the algorithm were more likely than manually drawn contours to be considered acceptable by the oncologists. The mean proportions of acceptable contours were 93% (automatic) and 69% (manual). Automatic delineation of the spinal canal was deemed to be successful on 91% of the images, unsuccessful on 2% of the images, and requiring further editing on 7% of the images. Our deformable template algorithm thus gives a robust segmentation of the spinal canal on CT images. The method can be extended to other structures, although it remains to be shown that chamfer matching is sufficiently robust for the delineation of soft-tissue structures surrounded by soft tissue

Additional details

Identifiers

Publishing Information

Journal Title
Medical Physics
Journal Volume
31
Journal Issue
2
Journal Page Range
p. 251-263
ISSN
0094-2405
CODEN
MPHYA6

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
35094694
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ALGORITHMS; COMPUTERIZED TOMOGRAPHY; DEFORMATION; IMAGE PROCESSING; IMAGES; MEDICAL PERSONNEL; NEOPLASMS; PERFORMANCE; RADIOTHERAPY; SIMULATION
Descriptors DEC
DIAGNOSTIC TECHNIQUES; DISEASES; MATHEMATICAL LOGIC; MEDICINE; NUCLEAR MEDICINE; PERSONNEL; PROCESSING; RADIOLOGY; THERAPY; TOMOGRAPHY

Optional Information

Notes
(c) 2004 American Association of Physicists in Medicine.