What is the diagnostic performance of 18-FDG-PET/MR compared to PET/CT for the N- and M- staging of breast cancer?
Creators
- 1. Geneva University Hospital, Radiology Department, Geneva (Switzerland)
- 2. Centre Hospitallier Universitaire Vaudois, Radiology Department, Lausanne (Switzerland)
- 3. Geneva University Hospital, Gynecology Department, Geneva (Switzerland)
- 4. Geneva University Hospital, Nuclear Medicine Department, Geneva (Switzerland)
Description
To compare the diagnostic performance of 18-FDG-PET/MR and PET/CT for the N- and M- staging of breast cancer. Two independent readers blinded to clinical/follow-up data reviewed PET/MR and PET/CT examinations performed for initial or recurrent breast cancer staging in 80 consecutive patients (mean age = 48 12.9 years). The diagnostic confidence for lesions in the contralateral breast, axillary/internal mammary nodes, bones and other distant sites were recorded. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated. The standard of reference included pathology and/or follow-up 12 months. Nine of 80 patients had bone metastases; 13/80 had other distant metastases, 44/80 had axillary, 9/80 had internal mammary and 3/80 had contralateral breast tumours. Inter-reader agreement for lesions was excellent (weighted kappa = 0.833 for PET/CT and 0.823 for PET/MR) with similar reader confidence for the two tests (ICC = 0.875). In the patient-per-patient analysis, sensitivity and specificity of PET/MRI and PET/CT were similar (p 0.05). In the lesion-per-lesion analysis, the sensitivity of PET/MR and PET/CT for bone metastases, other metastases, axillary and internal mammary nodes, contralateral tumours and all lesions together was 0.924 and 0.6923 (p = 0.0034), 0.923 and 0.923 (p = 1), 0.854 and 0.812 (p = 0.157), 0.9 and 0.9 (p = 1), 1 and 0.25 (p = 0.083), and 0.89 and 0.77 (p = 0.0013) respectively. The corresponding specificity was 0.953 and 1 (p = 0.0081), 1 and 1 (p = 1), 0.893 and 0.92 (p = 0.257), 1 and 1 (p = 1), 0.987 and 0.99 (p = 1) and 0.96 and 0.98 (p = 0.0075) respectively. Reader confidence, inter-reader agreement and diagnostic performance per patient were similar with PET/MR and PET/CT. However, for all lesions together, PET/MR had a superior sensitivity and lower specificity in the lesion-per-lesion analysis. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-018-5720-8Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 29
- Journal Issue
- 4
- Journal Page Range
- p. 1787-1798
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 50068008
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CARCINOMAS; COMPARATIVE EVALUATIONS; DIAGNOSIS; IMAGE PROCESSING; MAMMARY GLANDS; METABOLISM; METASTASES; NMR IMAGING; PERFORMANCE; POSITRON COMPUTED TOMOGRAPHY; RELAXATION TIME; SENSITIVITY; SKELETAL DISEASES; SPECIFICITY; VERTEBRAE; WEIGHTING FUNCTIONS
- Descriptors DEC
- BODY; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DISEASES; EMISSION COMPUTED TOMOGRAPHY; EVALUATION; FUNCTIONS; GLANDS; NEOPLASMS; ORGANS; PROCESSING; SKELETON; TOMOGRAPHY