Performance and limits of high-resolution CT systems

  • 1. IzfP, Saarbruecken (Germany)

Description

μCT systems require high-resolution radiographic equipment which use either a conventional X-ray tube together with a high-resolution detector, or a microfocus X-ray tube a medium-resolution detector. Large-size specimens have to be examinated with a high-resolution detector, which requires very long measuring periods, but on the other hand allows the calculation of high-resolution image reconstructions. The medium-resolution detectors have to be combined with a (more expensive) microfocus X-ray tube but permit to examine large-size specimens without translation (rotation scanning system). With a constant contrast resolution, the required measuring time increases with increasing geometric resolution. With given pixel widths of 25 μm and a measuring time of 30 minutes, the noise will amount to approx. 10%. (HP)

Availability note (English)

Available from FIZ Karlsruhe.

Abstract (German)

μCT Systeme benoetigen hochaufloesende Radiographiesysteme, die mittels einer konventionellen Roentgenroehre und einem hochaufloesenden Detektor oder aus einer Mikrofokus Roentgenroehre und einem mittelaufloesenden Detektor aufgebaut werden. Groessere Bauteile muessen mit einem hochaufloesenden Detektor abgescannt werden; dies verlaengert die Messzeit erheblich, ermoeglicht aber gleichzeitig die Berechnung hochaufloesender Rekonstruktionen. Mittelaufloesende Detektoren benoetigen eine (teuere) Mikrofokus-Roentgenroehre, erlauben aber die Messung groesserer Bauteile ohne Translation (reiner Rotationsscanner). Bei konstanter Kontrastaufloesung nimmt mit zunehmender geometrischer Aufloesung die Messzeit zu. Bei einer Pixelbreite von 25 μm und einer Messzeit von 30 Minuten, liegt das Rauschen bei rund 10%. (HP)

Additional details

Additional titles

Original title (German)
Realisierung und Grenzen hochaufloesender CT-Systeme

Publishing Information

Imprint Title
Computed tomography
Imprint Pagination
109 p.
Journal Issue
no. 22
Series
DGZfP-Berichtsband.
Journal Page Range
p. 43-52.

Conference

Title
2. seminar on computer tomography (CT).
Original Conference Title
2. Seminar ueber Computertomografie (CT)
Dates
11-12 Mar 1991.
Place
Muenchen (Germany).

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
23087024
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ALGORITHMS; COMPUTERIZED TOMOGRAPHY; IMAGE SCANNERS; NONDESTRUCTIVE TESTING; RESOLUTION; TIME DEPENDENCE; X-RAY RADIOGRAPHY; X-RAY SOURCES
Descriptors DEC
MATERIALS TESTING; RADIATION SOURCES; TESTING; TOMOGRAPHY

Optional Information

Notes
Imprint:Computertomografie.;Vortraege.