Published 1990 | Version v1
Report Open

Reactor coolant pump monitoring and diagnostic system

  • 1. Argonne National Lab., IL (USA)
  • 2. Maryland Univ., Baltimore, MD (USA)

Description

In order to reliably and safely operate a nuclear power plant, it is necessary to continuously monitor the performance of numerous subsystems to confirm that the plant state is within its prescribed limits. An important function of a properly designed monitoring system is the detection of incipient faults in all subsystems (with the avoidance of false alarms) coupled with an information system that provides the operators with fault diagnosis, prognosis of fault progression and recommended (either automatic or prescriptive) corrective action. In this paper, such a system is described that has been applied to reactor coolant pumps. This system includes a sensitive pattern-recognition technique based upon the sequential probability ratio test (SPRT) that detects incipient faults from validated signals, an expert system embodying knowledge bases on pump and sensor performance, extensive hypertext files containing operating and emergency procedures as well as pump and sensor information and a graphical interface providing the operator with easily perceived information on the location and character of the fault as well as recommended corrective action. This system is in the prototype stage and is currently being validated utilizing data from a liquid-metal cooled fast reactor (EBR-II). 3 refs., 4 figs

Availability note (English)

MF available from INIS under the Report Number; NTIS, PC A02/MF A01 as DE90011168; OSTI; INIS; US Govt. Printing Office Dep.

Files

21090492.pdf

Files (210.1 kB)

Name Size Download all
md5:3317fe8fbac561f14c758f2c434575bb
210.1 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
6 p.
Report number
CONF-901090--1

Conference

Title
2. international machinery monitoring and diagnostic conference.
Dates
22-25 Oct 1990.
Place
Los Angeles, CA (USA).

Optional Information

Contract/Grant/Project number
Contract W-31109-ENG-38