Published 2014 | Version v1
Journal article

ESR Dosimetric Properties of Sodium Glutamate

  • 1. Radiation Protection and Dosimetery, Dept., National Centre for Radiation Research and Technology (NCRRT). P. O. Box: Nasr City, Cairo (Egypt)

Description

Mono Sodium Glutamate powder and rods (3x 10 mm) were studied to be a radiation sensitive material for ESR dosimetry. Samples were irradiated with 60Co γ- rays. The developed signal after irradiation increases with the increase of the mono sodium glutamate in the rods. The prepared powder can be used in the dose range from (10-90) kGy, whereas the rods are useful in the range from (10-120) kGy. The obtained number of free radicals per 100ev (G value) was found to be 0.201± 0.01. The g factor is 2.0113± 0.0001. The rods have the advantage of negligible humidity effects during irradiation. The pre and post irradiation stability was found to be satisfactory.

Additional details

Publishing Information

Journal Title
Egyptian Journal of Radiation Sciences and Applications
Journal Volume
27
Journal Issue
1-2
Journal Page Range
p. 151-164
ISSN
1110-0303
CODEN
EJRAES