Published 1994 | Version v1
Report Open

Accounting for segment correlations in segmented gamma-ray scans

Description

In a typical segmented gamma-ray scanner (SGS), the detector's field of view is collimated so that a complete horizontal slice or segment of the desired thickness is visible. Ordinarily, the collimator is not deep enough to exclude gamma rays emitted from sample volumes above and below the segment aligned with the collimator. This can lead to assay biases, particularly for certain radioactive-material distributions. Another consequence of the collimator's low aspect ratio is that segment assays at the top and bottom of the sample are biased low because the detector's field of view is not filled. This effect is ordinarily countered by placing the sample on a low-Z pedestal and scanning one or more segment thicknesses below and above the sample. This takes extra time, however, We have investigated a number of techniques that both account for correlated segments and correct for end effects in SGS assays. Also, we have developed an algorithm that facilitates estimates of assay precision. Six calculation methods have been compared by evaluating the results of thousands of simulated, assays for three types of gamma-ray source distribution and ten masses. We will report on these computational studies and their experimental verification

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE94016096; NTIS; US Govt. Printing Office Dep.

Files

26012074.pdf

Files (683.2 kB)

Name Size Download all
md5:c1594b765f9bace4a8badc3d5f4df69b
683.2 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
6 p.
Report number
LA-UR--94-2561

Conference

Title
Institute of Nuclear Materials Management annual meeting.
Dates
17-20 Jul 1994.
Place
Naples, FL (United States).

Optional Information

Contract/Grant/Project number
Contract W-7405-ENG-36
Funding organization
USDOE, Washington, DC (United States).
Secondary number(s)
CONF-940748--48.