A review of the methods to measure the ion temperature in a tokamak plasma

Description

The most important methods to measure the ion temperatu--re in a Tokamak plasma are reviewed, e.g. energy analysis of the fast neutrals which leave out the plasma, Doppler broadening of the emision spectral lines and fusion neutron analysis. It is discussed their bounds so as the advantages and drawbacks of each one. Other methods of some interest in the future are outlined. (author)

Availability note (English)

MF available from INIS under the Report Number.

Abstract (Spanish)

Se presenta una revision de los metodos de medida de la temperatura ionica utilizados hasta el presente en los Tokamaks: analisis energetico de los neutros que escapan del plasma, medida del ensanchamiento Doppler de las lineas de emision y analisis de los neutrones de fusion. Se discuten sus limites de aplicacion, asi como las ventajas e inconvenientes de cada uno de ellos. Se senalan tambien otros metodos que seran de gran interes en los futuros tokamaks. (autor)