Tank vapor characterization project - Tank 241-U-112 headspace gas and vapor characterization: Results for homogeneity samples collected on December 6, 1996

Description

This report presents the results of analyses of samples taken from the headspace of waste storage tank 241-U-112 (Tank U-112) at the Hanford Site in Washington State. Samples were collected to determine the homogeneity of selected inorganic and organic headspace constitutents. Two risers (Riser 3 and Riser 6) were sampled at three different elevations (Bottom, Middle, and Top) within the tank. Tank headspace samples were collected by SGN Eurisys Service Corporation (SESC) and were analyzed by Pacific Northwest National Laboratory (PNNL) to determine headspace concentrations of selected non-radioactive analytes. Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Ammonia was determined to be above the immediate notification limit specified by the sampling and analysis plan

Availability note (English)

Available from INIS in electronic form and/or on microfiche ; Also available from OSTI as DE97054525; NTIS; US Govt. Printing Office Dep.

Files

29024770.pdf

Files (3.5 MB)

Name Size Download all
md5:87ff2f052f11ad1c954dbfbf18a06910
3.5 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
149 p.
Report number
PNNL--11607