Published August 15, 1986 | Version v1
Report

CW accelerators suitable for spallation neutron sources

Creators

  • 1. Chalk River Nuclear Labs., Ontario

Description

An accelerator-driven steady state neutron source will require a high current, high energy, 100% duty factor accelerator. No suitable accelerator has yet been built, but the technology to do so exists and examples of all of the likely components have been tested. This paper reviews some of the component test programs with comments on the problems specific to this application

Additional details

Publishing Information

Imprint Title
Nuclear Instruments and Methods in Physics Research. Section A: accelerators, spectrometers, detectors and associated equipment. Volume A249, No. 1
Journal Page Range
p. 102-115.
Report number
CONF-851268--

Conference

Title
Workshop on an advanced steady state neutron facility.
Dates
16-17 Dec 1985.
Place
Gaithersburg, MD (USA).