Synopsis of the results of a test of a reinforced concrete containment

Description

Sandia National Laboratories completed the testing of a 1:6-scale containment building for a Light Water Reactor in July 1987. The containment building was made of reinforced concrete and had many of the features found in full-size containments. The test program consisted of a structural integrity test, and integrated leak rate test, and concluded with an over pressurization test of the structure. The subject paper will emphasize the overpressurization test of the containment model

Availability note (English)

Available from NTIS, PC A03; 3 as DE88012415.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
17 p.
Report number
SAND--88-0548C

Conference

Title
4. workshop on integrity of containments for nuclear power plants.
Dates
15-17 Jun 1988.
Place
Washington, DC (USA).

Optional Information

Notes
Paper copy only, copy does not permit microfiche production.
Secondary number(s)