Published 1983 | Version v1
Report Open

Transient two-phase performance of LOFT reactor coolant pumps

Description

Performance characteristics of Loss-of-Fluid Test (LOFT) reactor coolant pumps under transient two-phase flow conditions were obtained based on the analysis of two large and small break loss-of-coolant experiments conducted at the LOFT facility. Emphasis is placed on the evaluation of the transient two-phase flow effects on the LOFT reactor coolant pump performance during the first quadrant operation. The measured pump characteristics are presented as functions of pump void fraction which was determined based on the measured density. The calculated pump characteristics such as pump head, torque (or hydraulic torque), and efficiency are also determined as functions of pump void fractions. The importance of accurate modeling of the reactor coolant pump performance under two-phase conditions is addressed. The analytical pump model, currently used in most reactor analysis codes to predict transient two-phase pump behavior, is assessed

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE84005123.

Files

15046438.pdf

Files (417.2 kB)

Name Size Download all
md5:897e42211b539ba4cfdf48061ae783ae
417.2 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
11 p.
Report number
CONF-831111--16

Conference

Title
ASME winter annual meeting.
Dates
13-18 Nov 1983.
Place
Boston, MA (USA).