Published 2001 | Version v1
Miscellaneous Open

Assessment of the unavailability and frequency of requests for the Auxiliary Feedwater System for WWER-440

  • 1. Technical University, Sofia (Bulgaria)
  • 2. Risk Engeneering Ltd, Sofia (Bulgaria)

Description

The report provides an analysis using results and techniques of PSA for studying of the Auxiliary Feedwater System of the steam generator. Since this is a fundamentally new system oriented to be an essential tool for the management of beyond design basis accidents and severe accidents, there were assessed both the unavailability of the system to perform its functions and the frequency of request

Files

46101990.pdf

Files (1.2 MB)

Name Size Download all
md5:1c1eb65be0cb73607b151501293ef491
1.2 MB Preview Download

Additional details

Additional titles

Original title (Bulgarian)
Оценка на неготовността и честотата на поискване на допълнителна система за аварийна питателна вода за ВВЕР-440

Publishing Information

Imprint Pagination
6 p.
Report number
INIS-BG--2158

Conference

Title
Annual Conference of the Faculty of Power Engineering and Power Machines
Acronym
FPEPM 2001
Dates
19-21 Sep 2001
Place
Sozopol (Bulgaria)

Optional Information

Notes
3 figs, 2 tabs., 3 refs.