Heavy ion accelerator (UTI-2)
Description
The design and test results of the 2 MeV ion accelerator designed for science of materials are described. The UTI-2 accelerator is developed on the basis of the UTI-1 accelerator and equipped with an injector of five-charge ions of iron, chromium and other elements with beam intensity of 50-100 μA, source electromagnet, mass-separator, accelerating system, target complex, a system for doping materials and powders of different metals and alloys. The test results pointed out that metal ion beams with 4-6 charge degree and intensity up to 100 μA may be obtained by means of a plasma-arc source operating in a continuous mode. Metal ions in the total beam current makes up 55-85 %. Yield of multicharge ions grows with increase of magnetic field strength and power introduced into the charge. Beam emittance of multicharge ions does not exceed 40 cmxmrad. The UTI-2 accelerator may be used both for studies on physical radiation damages and works on semiconductor ion doping
Availability note (English)
MF available from INIS under the Report Number.Files
18073728.pdf
Files
(828.0 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:4ce5ef4921f68fbf9f7b33b46fbe521b
|
828.0 kB | Preview Download |
System files
(53.8 kB)
| Name | Size | Download all |
|---|
Additional details
Additional titles
- Original title (Russian)
-
Ускоритель тяжелых ионов (УТИ-2)
Publishing Information
- Imprint Pagination
- 19 p.
- Report number
- KFTI--86-21
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 18073728
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- BEAM EMITTANCE; ELECTROSTATIC ACCELERATORS; INTEGRATED CIRCUITS; ION BEAMS; ION DENSITY; ION SOURCES; MEV RANGE 01-10; MICRO AMP BEAM CURRENTS; MULTICHARGED IONS; NONDESTRUCTIVE TESTING; PERFORMANCE TESTING; TARGET CHAMBERS
- Descriptors DEC
- ACCELERATOR FACILITIES; ACCELERATORS; BEAM CURRENTS; BEAMS; CHARGED PARTICLES; CURRENTS; ELECTRONIC CIRCUITS; ENERGY RANGE; IONS; MATERIALS TESTING; MEV RANGE; TESTING
Optional Information
- Notes
- 14 refs.; 13 figs.; 3 tabs.