Published September 1996 | Version v1
Report Open

Design of helium-gas supplying facility of out-of-pile demonstration test for HTTR heat utilization system

  • 1. Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

Description

One of the objectives of the High-Temperature Engineering Test Reactor (HTTR) is to demonstrate effectiveness of high-temperature heat utilization. Prior to connect a heat utilization system to the HTTR, a series of out-of-pile demonstration test is indispensable to improve components' performance, to demonstrate operation, control and safety technologies and to verify analysis codes for design and safety evaluation. After critical review and discussion on the out-of-pile demonstration test, a test facility have been designed. In this report, a helium-gas supplying facility simulated the HTTR system was described in detail, which supplies High-temperature helium-gas of 900degC to a steam reforming facility mocking-up the HTTR heat utilization system. Components of the Helium Engineering Demonstration Loop (HENDEL) were selected to reuse in the helium-gas supplying facility in order to decrease construction cost. Structures and specifications of new components such as a high-temperature heater and a preheater were decided after evaluation of thermal and hydraulic performance and strength. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

28008884.pdf

Files (1.2 MB)

Name Size Download all
md5:dd2cff7a5b3c6e423d09501389f2ca87
1.2 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
51 p.
Report number