Published November 2016 | Version v1
Journal article

Assessment of patient dose and radiogenic risks during endoscopic retrograde cholangiopancreatography

  • 1. Prince Sattam Bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P.O.Box 422, Alkharj 11942 (Saudi Arabia)
  • 2. Faculty of Radiological Sciences and Medical Imaging, Alzaiem Alazhari University, Khartoum (Sudan)
  • 3. Radiological SciencesDepartment, College of Applied Medical Sciences, King Saud University, P. O.Box 10219, Riyadh 11433 (Saudi Arabia)
  • 4. Medical Diagnostic Imaging Department, College of Health Sciences, University of Sharjah (United Arab Emirates)
  • 5. Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

Description

Endoscopic retrograde cholangiopancreatography (ERCP) is an invasive technique that has been used for over 30 years in the diagnosis and management of pancreaticobiliary disorders. The objectives of this study were to evaluate the patient entrance surface air kerma doses (ESAK) and estimate the organ and effective doses during ERCP in three hospitals in Khartoum. A total of 55 patients were examined in three hospitals in Khartoum state, Sudan. Calibrated thermoluinescent dosimeters (TLD) were used to measure patients' ESAK. Organ and effective doses were estimated using National Radiological Protection Board (NRPB) software. The overall mean of ESAK for all ERCP procedures was 42.4 mGy. The mean patient ESAK in Fedail (A), Soba (B) and Ibn sena (C) hospitals were 26.7 mGy, 26.0 mGy and 72.4 mGy, respectively. The effective doses in three hospitals were 1.60, 1.56 and 2.67 mSv in that order and the overall mean effective dose was 1.94 mSv. Patient radiation doses vary widely among the hospitals. Patient ESAK is low compared to previous studies in the light of the current practice. Patient dose was decreased significantly in the last two decades. - Highlights: • Radiation dose was measured for patients during ERCP procedures. • Radiogenic risk per ERCP procedure was estimated. • Patient ESAK is low compared to previous studies in the light of the current practice. • Patient dose was decreased significantly in the last two decades due to advancement in imaging technology and protocols.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apradiso.2016.03.010

Additional details

Identifiers

DOI
10.1016/j.apradiso.2016.03.010;
PII
S0969-8043(16)30094-X;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
117
Journal Page Range
p. 65-69
ISSN
0969-8043
CODEN
ARISEF

Conference

Title
15. international symposium on solid state dosimetry
Acronym
ISSSD2015
Dates
26-30 Sep 2015
Place
Leon, Guanajuato (Mexico)

Optional Information

Copyright
Copyright (c) 2016 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.