Published 2009 | Version v1
Miscellaneous

Status of the SPring-8 linac

  • 1. Japan Synchrotron Radiation Research Institute, SPring-8, Sayo, Hyogo (Japan)

Description

In FY2008, the total operation time of SPring-8 injector linac was 5150 hours. The total downtime was 0.21% (The frequency of fault was 0.33 times per day) and as the stable as the last few years. In the first cycle, the electron gun modulator broke down due to an electric discharge in the PFN condenser. And the gun cathode heater power supply and grid bias power supply broke down in the 1st and 2nd cycle. A twin electron gun system was constructed to eliminate long-time interruption of the beam injections caused by electron gun's accidents. The thyratron stands were replaced with new ones which were designed to enhance their maintainability and reliability. These improvements have finally reduced the total fault rate of the modulators to 0.06 events per day. (author)

Part of:
Proceedings of the 6th annual meeting of Particle Accelerator Society of Japan

Additional details

Additional titles

Original title (Japanese)
Dai 6 kai nippon kasokuki gakkai nenkai

Publishing Information

Imprint Title
Proceedings of the 6th annual meeting of Particle Accelerator Society of Japan
Imprint Pagination
1177 p.
Journal Page Range
p. 9-11

Conference

Title
6. annual meeting of Particle Accelerator Society of Japan
Dates
5-7 Aug 2009
Place
Tokai, Ibaraki (Japan)

Optional Information

Notes
This CD-ROM can be used for WINDOWS, MACINTOSH; Acrobat Reader is included; Data in PDF format, Folder Name: papers, Paper ID: woopa01.pdf; 5 refs., 3 figs., 1 tab. Imprint:Dai 6 kai nippon kasokuki gakkai nenkai