Published October 2000
| Version v1
Miscellaneous
Consideration on the effect of undercooling in Delayed Hydride Cracking (DHC) tests
- 1. KAERI, Taejon (Korea, Republic of)
Description
The effects of the undercooling on DHCV, which can be applied in Delayed Hydride Cracking(DHC) tests after soaking treatment, have been investigated. DHC Velocity (DHCV) has been decreased to 1/2 when the amount of undercooling temperature is 10 .deg. C, and then DHCV's have been decreased to about 1/5 when the amount of undercooling temperature is 40 .deg. C. This behavior is interpreted in terms of Terminal Solid Solubility for Dissolution (TSSD) and Precipitation (TSSP), the nature of DHC, and the observed phenomenon of DHC. In order to explain the effects of undercooling on DHCV, the role of the existing hydride at DHC testing temperature on DHCV has been proposed
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Taejon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS autumn meeting
- Imprint Pagination
- [CD-ROM]
- Journal Page Range
- [9 p.]
Conference
- Title
- 2000 autumn meeting of the KNS
- Dates
- 26-27 Oct 2000
- Place
- Taejon (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 34050600
- Subject category
- S36: MATERIALS SCIENCE;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CRACKS; DISSOLUTION; HYDRIDES; PRECIPITATION; SOLUBILITY; VELOCITY
- Descriptors DEC
- HYDROGEN COMPOUNDS; SEPARATION PROCESSES
Optional Information
- Notes
- 3 refs, 7 figs