Operation of the cryogenic system for the Mirror Fusion Test Facility

Description

The cryogenic system for the Mirror Fusion Test Facility (MFTF) at Lawrence Livermore National Laboratory (LLNL) was designed to cool the entire MFTF-B system from ambient to operating temperature in less than 10 days. The system was successfully operated in the recent plant and capital equipment (PACE) acceptance tests, and results from these tests helped us correct problem areas and improve the system

Availability note (English)

Available from NTIS, PC A02/MF A01; 1 as DE87011553.

Files

19015286.pdf

Files (162.1 kB)

Name Size Download all
md5:4d7da6ddb1c7c12fa92da46c24d1e74b
162.1 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
11 p.
Report number
UCRL--96661

Conference

Title
Conference on advances in cryogenic engineering.
Dates
14-18 Jun 1987.
Place
St. Charles, IL (USA).

Optional Information

Notes
Portions of this document are illegible in microfiche products.