Structural analysis of the Browns Ferry spent fuel storage pool
Description
As part of a joint Spent Fuel Management Program with the Tennessee Valley Authority, General Electric Company recently completed a structural analysis of the spent fuel pool at the Browns Ferry nuclear power station to determine if the pool floor can accommodate storage of consolidated fuel. Both linear and non-linear elastic techniques were employed in the analysis with results that proved highly effective in establishing with confidence the adequacy of the safety margins available in the existing structures
Additional details
Publishing Information
- Imprint Title
- Third international spent fuel storage technology symposium/workshop: proceedings. Volume 2
- Journal Page Range
- p. W.333-W.338.
- Report number
- CONF-860417--Vol.2
Conference
- Title
- 3. international symposium/workshop on irradiated fuel storage.
- Dates
- 8-10 Apr 1986.
- Place
- Seattle, WA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 18023349
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- FUEL RACKS; MECHANICAL PROPERTIES; PACKAGING; SAFETY; SPENT FUEL ELEMENTS; SPENT FUEL STORAGE; WATER RESERVOIRS
- Descriptors DEC
- FUEL ELEMENTS; MECHANICAL STRUCTURES; REACTOR COMPONENTS; STORAGE; SUPPORTS; SURFACE WATERS