Published May 2008 | Version v1
Journal article

Diagnostic efficacy for coronary in-stent patency with parameters defined on Hounsfield CT value-spatial profile curves

  • 1. Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, University of Tokyo, Tokyo (Japan)
  • 2. Department of Radiology, Faculty of Medicine and Graduate School of Medicine, University of Tokyo, Tokyo (Japan)

Description

Purpose: Hounsfield CT values across coronary CT angiograms constitute CT value-spatial profile curves. These CT profile curves are independent of window settings, and therefore, parameters derived from the curves can be used for objective anatomic analyses. Applicability of parameters derived from the curves to quantification of coronary in-stent patency has not yet been evaluated. Methods: Twenty-five CT value-spatial profile curves were delineated from 10 consecutive coronary stents to test correlation between the curve derived parameter (i.e., the minimum extreme value normalized by dividing by the maximum value of the curves obtained at neighboring outside of stents) and three intravascular ultrasound (IVUS) parameters. Results: Correlation coefficients between normalized minimum extreme value of CT value-spatial profile curves and three IVUS parameters (such as patent cross-sectional in-stent area, the percentage of patent cross-sectional in-stent area, and coronary artery intra-stent diameter) were 0.65 (p < 0.01), 0.44 (p < 0.05) and 0.51 (p < 0.05), respectively. Conclusions: CT parameters defined on Hounsfield CT value-spatial profile curves correlated significantly with IVUS parameters for quantitative coronary in-stent patency. A new approach with CT coronary angiography is therefore indicated for the noninvasive assessment of in-stent re-stenosis

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radi.2006.12.004

Additional details

Identifiers

DOI
10.1016/j.radi.2006.12.004;
PII
S1078-8174(06)00148-9;

Publishing Information

Journal Title
Radiography (London 1995)
Journal Volume
14
Journal Issue
2
Journal Page Range
p. 98-104
ISSN
1078-8174

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
40005172
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; COMPUTERIZED TOMOGRAPHY; CORONARIES; IMAGE PROCESSING; PATENTS
Descriptors DEC
ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DOCUMENT TYPES; MEDICINE; NUCLEAR MEDICINE; ORGANS; PROCESSING; RADIOLOGY; TOMOGRAPHY

Optional Information