Published October 1985 | Version v1
Journal article

Treatment rationale in thyroid carcinoma. Effect of scan dose

  • 1. Cedars-Sinai Medical Center, Los Angeles, CA

Description

The authors have previously shown that the definition of ablation of thyroid tissue in patients treated with thyroidectomy and radioiodine (I-131) for thyroid carcinoma depends upon the dose of I-131 used to scan the patient. The therapeutic response to I-131 therapy was evaluated in a group of ten differentiated thyroid cancer patients who had a negative 2-mCi (-2 mCi) diagnostic study, but had a positive 10-mCi (+10 mCi) diagnostic study (group 1) during their follow-up evaluation. These results were compared to another group of ten differentiated thyroid cancer patients who received I-131 ablation therapy based on a positive 2-mCi (+2 mCi) I-131 scan (group 2). Six patients in group 1 and eight in group 2 had improvement or ablation of residual tissue based on the 10-mCi scan following therapy. The difference in response between the two groups was not statistically significant (P = 0.63) by two-tailed Fisher's exact test, indicating that even patients with -2-mCi, but +10-mCi scans may respond to I-131 therapy. Whether the large dose therapy makes any impact on the clinical outcome has not been answered by this study

Additional details

Publishing Information

Journal Title
Clin. Nucl. Med.
Journal Issue
no.10
Series
Clin. Nucl. Med.
ISSN
0363-9762
CODEN
CNMED