Published November 1980
| Version v1
Journal article
Steam-generator tube performance: world experience with water-cooled nuclear power reactors during 1978
Creators
Description
The performance of steam-generator tubes in water-cooled nuclear power reactors during 1978 is reviewed. Tube failures occurred at 31 of the 86 reactors surveyed. The causes of these failures and the procedures designed to deal with them are described. The number of tubes plugged has decreased dramatically in 1978 compared to the previous year. This is attributed to the diligent application of techniques developed through in-plant experience and research and development programs over the past several years
Additional details
Publishing Information
- Journal Title
- Nucl. Saf.
- Journal Volume
- 21
- Journal Issue
- 6
- Series
- Nucl. Saf.
- Journal Page Range
- 766-780
- ISSN
- 0029-5604
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 12596461
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Numerical Data
- Descriptors DEI
- COMPILED DATA; FAILURES; GLOBAL ASPECTS; NUCLEAR POWER PLANTS; PERFORMANCE; REVIEWS; STEAM GENERATORS; TUBES; WATER COOLED REACTORS
- Descriptors DEC
- BOILERS; DATA; DOCUMENT TYPES; INFORMATION; NUCLEAR FACILITIES; NUMERICAL DATA; POWER PLANTS; REACTORS; THERMAL POWER PLANTS; VAPOR GENERATORS