Published October 1998 | Version v1
Journal article

Analyses of subcooled CCFL tests for evaluation of WCOBRA/TRAC applicability

  • 1. Westinghouse Electric Corp., Pittsburgh, PA (United States). Nuclear Service Div.

Description

The WCOBRA/TRAC-MOD7A, Rev. 1 code is currently licensed for best estimate large break LOCA analyses of 3 and 4 loop PWRs with emergency core cooling system injection located in the cold legs. As a part of the licensing effort to extend the code applicability to an upper plenum injection plant, the codes ability to predict subcooled flooding on a perforated plate was assessed by analyses of GE counter current flow limit tests and by comparison to the Bankoff flooding correlation (Bankoff et al. (1981)). The observed code model bias for subcooled CCFL can be eliminated by applying multiplication factors to the interfacial condensation and the interfacial drag models. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Engineering and Design
Journal Volume
185
Journal Issue
2-3
Journal Page Range
p. 127-140
ISSN
0029-5493
CODEN
NEDEAU

Optional Information

Notes
9 refs.