Published February 1978 | Version v1
Journal article

Determination of plasma oxytocin by radioimmunoassay

  • 1. Fukushima Medical Coll. (Japan)

Description

A simple radioimmunoassay was applied to the measurement of oxytocin in human plasma. A high specificity of immunoassay was demonstrated by the fact that large excess of angiotensin I and II, and ACTH did not displace labelled oxytocin from the antibody. Lysine-8-vasopressin and arginine-8-vasopressin showed very little cross-reaction in the assay, possessing only 0.002% of the immunological potency of oxytocin. The specific activity of 125I-oxytocin was 166 μCi/μg. Adsorption and extraction capacities of Florisil were 96.6 +- 2.1% and 85.7 +- 2.5%, respectively. Intra- and inter-assay variability were 7.2 +- 4.9% and 4.3 +- 2.2%, respectively. The sensitivity of the assay was below 1 pg/tube. Normal levels of plasma oxytocin were 0 - 2.2 pg/ml (n=13) in males and 0 - 10.4 pg/ml (n=10) in females. Plasma oxytocin levels in the 39th and 40th weeks of pregnancy were 27.9 +- 4.14 pg/ml (n=4) and 29.8 +- 17.1 pg/ml (n=13), respectively. The levels increased to 33.1 +- 12.1 pg/ml (n=7) and 37.1 +- 17.5 pg/ml (n=7) in the first and third stages of labor, and decreased to 13.6 +- 5.25 pg/ml (n=6) on the 2nd to 8th day after labor. The radioimmunoassay for oxytocin in plasma is considered to be sufficiently applicable for clinical use. (auth.)

Additional details

Publishing Information

Journal Title
Folia Endocrinologica Japonica
Journal Volume
54
Journal Issue
2
Series
Nippon Naibunpi Gakkai Zasshi.
Journal Page Range
107-116
ISSN
0029-0661

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent