Reactor building integrity test at Gentilly 2
Description
This paper describes the reactor building integrity test at Gentilly 2 reactor facility. Since commissioning, the containment integrity has to be demonstrated to the safety authority every three years for the major components: the reactor building, the air locks, and the containment valves. The method used is a pressure test at 124 kPad. This activity requires 7 days and it costs $350, 000. From 1987 to 1989, Hydro-Quebec has invested resources to develop this test referred to as the TCM method. This method was implemented between 1990 and 1991 and is now applied every three years
Additional details
Publishing Information
- Publisher
- Canadian Nuclear Society
- Imprint Place
- Toronto, Ontario (Canada)
- ISBN
- 0-919784-68-2
- Imprint Title
- 5. International conference on CANDU maintenance
- Imprint Pagination
- 326 p.
- Journal Page Range
- p. 33-50
Conference
- Title
- 5. international conference on CANDU maintenance
- Dates
- 19-21 Nov 2000
- Place
- Toronto, Ontario (Canada)
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 35089492
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CANADIAN AECB; CANDU TYPE REACTORS; CONTAINMENT BUILDINGS; GENTILLY REACTOR; PRESSURE MEASUREMENT; REACTOR SAFETY
- Descriptors DEC
- BUILDINGS; CANADIAN ORGANIZATIONS; CANDU TYPE REACTORS; CONTAINMENT; HEAVY WATER MODERATED REACTORS; HWLWR TYPE REACTORS; NATIONAL ORGANIZATIONS; NATURAL URANIUM REACTORS; POWER REACTORS; PRESSURE TUBE REACTORS; REACTORS; SAFETY; THERMAL REACTORS; WATER COOLED REACTORS