The Instrumentation and Telemetry Departments at Sandia National Laboratories have been exploring the instrumentation of sealed canisters where the flight application will not tolerate either the presence of a chemical power source or penetration by power supply wires. This paper will describe the application of a low power micro-controller based instrumentation system that uses magnetic coupling for both power and data to support a flight application
Availability note (English)
Available from INIS in electronic form; ALSO AVAILABLE FROM OSTI AS DE00007267; NTIS; US GOVT. PRINTING OFFICE DEP.