Published September 2007 | Version v1
Journal article

Comparison radiation dose of Z-axis automatic tube current modulation technique with fixed tube current multi-detector row CT scanning of lower extremity venography

  • 1. Wonkwang Health Science College, Iksan (Korea, Republic of)
  • 2. Seoul National Univ. Hospital, Seoul (Korea, Republic of)
  • 3. Presbyterian Medical Center, Jeonju (Korea, Republic of)
  • 4. Hanyang Univ., Seoul (Korea, Republic of)

Description

Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of Multi-Detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, 70∼450 mA). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, Z-axis modulation resulted in reduction of CTDIvol (range, -6.5%∼-35.6%) and DLP (range,-0.2%∼-20.2%). Compared with manually selected fixed tube current, Z-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography

Additional details

Publishing Information

Journal Title
Journal of the Korean Association for Radiation Protection
Journal Volume
32
Journal Issue
3
Series
35 refs, 8 figs, 5 tabs
Journal Page Range
p. 123-133
ISSN
0253-4231

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
39096588
Subject category
S63: RADIATION, THERMAL, AND OTHER ENVIRONMENTAL POLLUTANT EFFECTS ON LIVING ORGANISMS AND BIOLOGICAL MATERIALS;
Descriptors DEI
DATA ACQUISITION; DIAGNOSTIC TECHNIQUES; MODULATION; MONTE CARLO METHOD; NOISE; RADIATION DOSES
Descriptors DEC
CALCULATION METHODS; DOSES