Published June 23, 2010 | Version v1
Journal article

Characterizations and Applications of the Insertion Device of the SPring-8 Diagnostics Beamline II

  • 1. Japan Synchrotron Radiation Research Institute (JASRI/SPring-8), 1-1-1 Kouto, Sayo, Hyogo (Japan)
  • 2. High Energy Accelerator Research Organization (KEK)/Institute of Materials Structure Science, 1-1 Oho, Tsukuba, Ibaraki (Japan)

Description

An insertion device (ID05) of the SPring-8 diagnostics beamline II (BL05SS) was characterized from the aspects of both the magnetic field performance and the spectral performance as a high K wiggler, which was confirmed to have the field performance with the rms phase error less than 2 degree. Meanwhile, the spectral performance of ID05 as an undulator with small K was also investigated by the energy spectrum measurements. The rms phase error less than 2degree leads us to apply the wiggler radiation on the higher harmonics to the beam diagnostics. We successfully demonstrated an application to the energy-spread diagnostics of electron beam using the 19th harmonics.

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
1234
Journal Issue
1
Journal Page Range
p. 560-563
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
10. international conference on radiation instrumentation
Acronym
SRI 2009
Dates
27 Sep - 2 Oct 2009
Place
Melbourne (Australia)

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
42003451
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ELECTRON BEAMS; ENERGY SPECTRA; GRATINGS; HARMONIC GENERATION; MAGNETIC FIELDS; PERFORMANCE; SPRING-8 STORAGE RING; WIGGLER MAGNETS
Descriptors DEC
BEAMS; EQUIPMENT; FREQUENCY MIXING; LEPTON BEAMS; MAGNETS; PARTICLE BEAMS; RADIATION SOURCES; SPECTRA; STORAGE RINGS; SYNCHROTRON RADIATION SOURCES

Optional Information

Notes
(c) 2010 American Institute of Physics