Some factors affecting the metering of subcooled water with a choked venturi

Description

A series of experiments was performed to characterize the subcooled choking process in a convergent-divergent nozzle with a constant-area throat. The experiments were conducted in a low-pressure flow loop capable of a maximum water flow rate of 5.5 L/s with a pressure head of 300 kPa. The pressure and temperature upstream of the nozzle in the flow loop were adjusted between 90 and 300 kPa and 53 and 960C, respectively. The variables measured in this study of critical flow phenomena were the flow rate, upstream pressure and temperature, and the axial wall pressure profiles in the nozzle. Critical mass flow rate data were acquired along five isotherms as a function of stagnation pressure. Factors affecting metering performance are examined

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

12624832.pdf

Files (451.1 kB)

Name Size Download all
md5:d2772eb77339301f08a051bbd582e8cb
451.1 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
14 p.
Report number
CONF-810406--4

Conference

Title
27. international instrumentation symposium.
Dates
27 - 30 Apr 1981.
Place
Indianapolis, IN, USA.

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
12624832
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CAVITATION; CRITICAL FLOW; FLOW RATE; LOSS OF COOLANT; NOZZLES; PWR TYPE REACTORS; VENTURI TUBES
Descriptors DEC
ACCIDENTS; FLUID FLOW; REACTOR ACCIDENTS; REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS