Published May 1989 | Version v1
Miscellaneous

Measurement and control of level height in nuclear power plant steam generators

Creators

  • 1. Vitkovicke Zelezarny a Strojirny Klementa Gottwalda, Ostrava (Czechoslovakia). Vyzkumny Ustav Metalurgicky

Description

The steam-water mixture level in horizontal steam generators is measured and controlled by means of one-chamber and two-chamber levelling vessels. Mathematical relations are given for converting the level indicator readings to actual level heights. The effect of the level indicator attachment height on this data conversion is discussed. It turns out that the practised steam-water level height measurement procedure by means of hydrostatic level indicators is not accurate enough for control purposes. (E.J.). 3 figs., 4 refs

Part of:
Upgrading the operating reliability and lifetime of PWR-type nuclear power plant steam generators. Vol. 1,2

Additional details

Additional titles

Original title (Czech)
Problematika mereni a regulace vysky hladiny v PG JE

Publishing Information

Imprint Title
Upgrading the operating reliability and lifetime of PWR-type nuclear power plant steam generators. Vol. 1,2
Imprint Pagination
372 p.
Journal Page Range
p. 55-60.
Report number
INIS-mf--12809(v.1,2)

Conference

Title
National conference ''Upgrading the operating reliability and lifetime of PWR-type nuclear power plant steam generators''.
Original Conference Title
Zvysovani provozni spolehlivosti a zivotnosti parnich generatoru jadernych elektraren tlakovodniho typu
Dates
17-19 May 1989.
Place
Ostrava (Czechoslovakia).

INIS

Country of Publication
Serbia and Montenegro
Country of Input or Organization
Serbia and Montenegro
INIS RN
22038127
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
FEEDWATER; LEVEL INDICATORS; LEVELS; MATHEMATICAL MODELS; STEAM; STEAM GENERATORS; THERMODYNAMICS; TWO-PHASE FLOW
Descriptors DEC
BOILERS; FLUID FLOW; HYDROGEN COMPOUNDS; MEASURING INSTRUMENTS; OXYGEN COMPOUNDS; VAPOR GENERATORS; WATER

Optional Information

Notes
Imprint:Published in 2 volumes.;Zvysovani provozni spolehlivosti a zivotnosti parnich generatoru jadernych elektraren tlakovodniho typu. Dil 1,2.