Published 1998 | Version v1
Journal article

Radiation Dose and Image Quality in Spiral Computed Tomography: Results of a Multi-Centre Study at Eight Radiological Institutions

Description

To evaluate radiation dose (expressed as PCTDI or DAVE) in correlation to image quality, seven clinical protocols were measured in eight radiological departments provided with six different types of high-end spiral CT scanners of the latest generation. Central and surface PCTDI for seven clinically applied protocols and one standardised liver protocol were determined with a dedicated phantom and ionisation chamber. For low contrast measurements, a cylindrical 3D phantom (different sized spheres of defined contrast) was used. Image noise was measured with a cylindrical water phantom, high contrast resolution with a Perspex hole phantom. Images were randomised, made anonymous and read by eight radiologists (one from each institution). Radiation output (PCTDI per 100 mA.s) for six different scanners varied by a factor between 1.7 (central PCTDI) and 2.0 (surface PCTDI) for the standardised protocol and by a factor of 4.3 for the 1 mm inner ear protocol. For seven clinically applied protocols of six radiological departments doses (expressed as DAVE/pitch) varied by factors between 1.7 (head protocol) and 8.3 (abdomen paediatric protocol). Low contrast detectability correlated closely with dose. An improvement in detection from 8 mm to 4 mm sized spheres needed approximately a tenfold increase in dose. Differences of modern CT scanner technology seem to be of minor importance for radiation exposure compared with selection of protocol parameters in different radiological institutes. Future discussion on guidelines, e.g. reference doses, should consider optimisation of tube current according to the individual patient and the clinical indication. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
80
Journal Issue
1-3
Journal Page Range
p. 283-286
ISSN
0144-8420
CODEN
RPDODE

Conference

Title
Workshop on reference doses and quality in medical imaging
Dates
23-25 Oct 1997
Place
Luxembourg (Luxembourg)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
Kazakhstan
INIS RN
31044190
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; IMAGE SCANNERS; IMAGES; QUALITY CONTROL; RADIATION DOSES
Descriptors DEC
CONTROL; DIAGNOSTIC TECHNIQUES; DOSES; EVALUATION; TOMOGRAPHY