Charge-exchange recombination spectroscopy measurements of ion temperature and plasma rotation in PBX
Description
The primary diagnostic on PBX for ion temperature measurements is charge-exchange recombination spectroscopy of low Z ions, wherein fast neutrals from the heating neutral beams excite spectral lines from highly excited states (n greater than or equal to 4) of hydrogenic 0, C, and He via charge-exchange collisions with the respective fully stripped ions. Since the neutral beams on PBX provide relatively low velocity neutrals (i.e., D0 beams at 44 keV), the best signals are obtained using the near-uv lines of 07+ (e.g., n = 8-7, 2976 A). Off-line analysis of the Doppler broadened and shifted line profiles includes non-linear least squares fitting to a model line profile, while a simplified on-line fast analysis code permits between-shot data analysis
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE85003709.Files
16047696.pdf
Files
(355.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:3dae7790819a948a02981eea5d709a4b
|
355.6 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 17 p.
- Report number
- PPPL--2172
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 16047696
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- CHARGE EXCHANGE; ION TEMPERATURE; NEUTRAL ATOM BEAM INJECTION; PDX DEVICES; PLASMA; PLASMA DIAGNOSTICS; RECOMBINATION; ROTATION
- Descriptors DEC
- BEAM INJECTION