Published May 1984 | Version v1
Journal article

Highly sensitive microcalorimeters for radiation research

Description

Calorimetry is used in research at various types of nuclear-physics installations to obtain information on the quantitative and qualitative composition of ionizing radiation in a reactor core and in the surrounding layers of the biological shield. In this paper, the authors examine the characteristics of highly sensitive microcalorimeters with modular semiconductor heat pickups designed for operation in reactor channels. The microcalorimeters have a thin-walled aluminum housing on whose inner surface modular heat pickups are placed radially as shown here. The results of measurements of the temperature dependence of the sensitivity of the microcalorimeters are shown. The results of measuring the sensitivity of a PMK-2 microcalorimeter assembly as a function of integrated neutron flux for three energy intervals and the adsorbed gamma energy are shown. In order to study specimens with different shapes and sizes, microcalorimeters with chambers in the form of cylinders and a parallelepiped were built and tested

Additional details

Publishing Information

Journal Title
Meas. Tech. (Engl. Transl.)
Journal Volume
26
Journal Issue
12
Series
Meas. Tech. (Engl. Transl.).
Journal Page Range
1015-1018
ISSN
0543-1972
CODEN
MSTCA

Optional Information

Notes
Translated from Izmer. Tekh.; 26: No. 12, 46-48(Dec 1983).