Published 1978 | Version v1
Book

Hinkley Point B Power Station, radiation protection, design philosophy and operating experience

  • 1. Central Electricity Generating Board, Barnwood (UK). Generation Development and Construction Div.

Description

The paper describes the major design aspects of the Hinkley Point 'B' Advanced Gas Cooled Reactor (AGR) which are required for radiation protection purposes. It includes a description of the design criteria, the predicted sources of radioactivity, radiation levels and individual exposures. Where possible, operation experience is also given. (author)

Additional details

Publishing Information

Publisher
British Nuclear Energy Society.
Imprint Place
London
ISBN
0 7277 0072 3
Imprint Title
Radiation protection in nuclear power plants and the fuel cycle. Volume 2
Journal Page Range
p. 175-179.

Conference

Title
Conference on radiation protection in nuclear power plants and the fuel cycle.
Dates
27 Nov - 1 Dec 1978.
Place