Published February 1982 | Version v1
Report Open

Discharge breakdown in the EXTRAP configuration

Description

The breakdown of a discharge in a linear EXTRAP configuration has been studied experimentally. In this configuration the breakdown occurs along the zero B-field line, which is the axis of the linear octupole magnetic field, between the anode and cathode which constitute the ends of the linear device. Breakdown could be described by a modified Townsend criterion which included additional electron losses due to the presence of the B-field transverse to the discharge. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

13681380.pdf

Files (310.7 kB)

Name Size Download all
md5:dd72dde825611443210cd73b411f9fa0
310.7 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
14 p.
Report number
TRITA-PFU--82-04

INIS

Country of Publication
Sweden
Country of Input or Organization
Sweden
INIS RN
13681380
Subject category
S75: CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY;
Descriptors DEI
BREAKDOWN; MAGNETIC FIELDS; TOWNSEND DISCHARGE
Descriptors DEC
ELECTRIC DISCHARGES