Analysis of magnetic field measurement results for the AGS Booster magnets

Description

Magnetic field measurements have been made on nearly 200 conventional magnets that have been installed in the AGS Booster and its associated transfer lines. The measurements were intended to monitor the quality of the magnets being produced and to check the performance of each magnet before installation. The magnetic measurements effort led to certain improvements in the manufacturing process, which ten subsequently produced very good, very uniform magnets. The integrated dipole fields of the 36 booster dipoles are uniform to 1.5 parts in ten thousand. The magnetic measurements indicate that the quadrupoles were manufactured to an accuracy of 3 ten thousandths of an inch, which is better than we can physically measure. 3 refs., 2 figs., 4 tabs

Availability note (English)

MF available from INIS under the Report Number; OSTI as DE91013599; NTIS; INIS; US Govt. Printing Office Dep.

Files

22085203.pdf

Files (169.1 kB)

Name Size Download all
md5:5722ae3fae8be8d8fb778cbb8ac08df1
169.1 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
3 p.
Report number
BNL--45425

Conference

Title
1991 Institute of Electrical and Electronics Engineers (IEEE) particle accelerator conference (PAC).
Dates
6-9 May 1991.
Place
San Francisco, CA (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
22085203
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BROOKHAVEN AGS; ERRORS; MAGNETIC FIELDS; MAGNETS; MEASURING METHODS; PARTICLE BOOSTERS; PERFORMANCE; QUADRUPOLES
Descriptors DEC
ACCELERATORS; CYCLIC ACCELERATORS; EQUIPMENT; MULTIPOLES; SYNCHROTRONS

Optional Information

Contract/Grant/Project number
Contract AC02-76CH00016
Funding organization
USDOE, Washington, DC (USA).
Secondary number(s)
CONF-910505--193.